SPEEDWALL® INTERTENANCY 

FOR APARTMENTS

Conventional framed wall systems rely on the internal linings for fire-resistance. Penetrating these linings potentially destroys the fire-rated barrier. In the Speedwall® Intertenancy System the main fire barrier located between frames is designed to protect the structure on the side opposite the fire.

 

 

 

 

 

Speedwall Systems Summary Table - for Apartments

SPEC. CODESTCFRRWALL THICKNESS*FRAMECAVITYSYSTEM SUMMARY
SIM01 57 -/60/60 194mm 964mm Steel frame
one side. 28mm
Furring channel the other
20mm one side Speedwall 51mm panels (600 Kg/m3 density) + 1 layer 13mm GIB® Standard each side
SIM02 57 -/60/60 122mm 28mm Furring
channel one side
N/A Speedwall 51mm panels (600 Kg/m3 density) + 1 layer 13mm GIB Noiseline® each side
SIM03 58 -/60/60 167mm 28mm Furring
channel each side
N/A  Speedwall 51mm panels (600 Kg/m3 density) + 1 layer 13mm GIB Noiseline® each side
SIM04 59 -/60/60 161mm 64mm Steel frame
one side
20mm one side Speedwall 51mm panels (600 Kg/m3 density) + 1 layer 13mm GIB® Standard each side
SIM05 68 -/60/60 240mm 64mm Steel frame
each side
20mm one side
15mm one side
Speedwall 51mm panels (600 Kg/m3 density) + 1 layer 13mm GIB® Standard each side
SIM06 59 -/120/120 188mm 64mm Steel frame
one side
20mm one side Speedwall 78mm panels (400 Kg/m3 density) + 1 layer 13mm GIB Noiseline® one side + 1 layer 13mm GIB® Standard other side
SIM07 56 -/120/120 188mm 64mm Steel frame
one side
20mm one side Speedwall 78mm panels (400 Kg/m3 density) + 1 layer 13mm GIB® Standard each side

Nominal measurement